Pressure Gauge Connectors
Use a DIN 2353 pressure gauge connector to connect a pressure gauge to the hydraulic tube circuit, matching the gauge thread and sealing arrangement.
Configuration illustration; supplied variant may differ.
Query product →Connect pressure instruments and diagnostic test points to hydraulic tube circuits. F-Line gauge connectors, swivel gauge adaptors and test couplings cover different instrument and tube interfaces.
ISO 8434-1 is the equivalent international standard for DIN 2353 24° cone tube connections.


Use a DIN 2353 pressure gauge connector to connect a pressure gauge to the hydraulic tube circuit, matching the gauge thread and sealing arrangement.
Configuration illustration; supplied variant may differ.
Query product →
Use a standpipe arrangement for the gauge connection.
Configuration illustration; supplied variant may differ.
Query product →
Orient the gauge using a swivel adaptor with the correct seal.
Configuration illustration; supplied variant may differ.
Query product →
A hydraulic test coupling provides a dedicated connection for diagnostic pressure measurement.
Configuration illustration; supplied variant may differ.
Query product →
Add a hydraulic pressure test point to a tube run using a tee test coupling.
Configuration illustration; supplied variant may differ.
Query product →Use the Fluidline part number in your enquiry. SS identifies stainless steel in this list; confirm the exact supplied grade and configuration.
Search all 105 Fluidline part numbers → · Browse dimensional tables ↓
For this range, request a Fluidline part number using the configuration and dimensions below.
Choose a configuration to open its drawing and sizes. Linear dimensions are in mm. Upper-case L and lower-case l are different drawing dimensions. A dash means the catalogue does not provide a value.

Dimensions in millimetres. Thread designations are shown separately. Match the letters to the drawing.
Catalogue drawing and table — page 56| Fluidline part number | Series | Tube OD (mm) | d | H | h | L | l | l1 | l2 | T |
|---|---|---|---|---|---|---|---|---|---|---|
| On enquiry | L | 6 | 2.5 | 14 | 19 | 37 | 7.5 | 14.5 | 4.5 | 1/4 |
| On enquiry | L | 8 | 5.5 | 17 | 19 | 37 | 7.5 | 14.5 | 4.5 | 1/4 |
| On enquiry | L | 10 | 5.5 | 19 | 19 | 38 | 8.5 | 14.5 | 4.5 | 1/4 |
| On enquiry | L | 12 | 5.5 | 22 | 19 | 38 | 8.5 | 14.5 | 4.5 | 1/4 |
| On enquiry | S | 6 | 3.5 | 17 | 27 | 46 | 11 | 20 | 5 | 1/2 |
| On enquiry | S | 8 | 3.5 | 19 | 27 | 46 | 11 | 20 | 5 | 1/2 |
| On enquiry | S | 10 | 7.0 | 22 | 27 | 47 | 10.5 | 20 | 5 | 1/2 |
| On enquiry | S | 12 | 7.0 | 24 | 27 | 47 | 10.5 | 20 | 5 | 1/2 |
Reference dimensions support selection. Confirm the supplied item drawing, material, seals and permissible operating conditions with your quotation.

Dimensions in millimetres. Thread designations are shown separately. Match the letters to the drawing.
Catalogue drawing and table — page 57| Fluidline part number | Series | Tube OD (mm) | H | h | L | l | S |
|---|---|---|---|---|---|---|---|
| On enquiry | L | 6 | 14 | 24 | 50 | 20.5 | 50 |
| On enquiry | L | 8 | 17 | 24 | 50 | 20.5 | 50 |
| On enquiry | L | 10 | 19 | 24 | 52 | 22.5 | 50 |
| On enquiry | L | 12 | 22 | 24 | 52 | 22.5 | 50 |
| On enquiry | L | 15 | 27 | 30 | 55 | 24.5 | 53 |
| On enquiry | L | 18 | 32 | 32 | 56 | 23.5 | 54 |
| On enquiry | L | 22 | 36 | 36 | 60 | 27.5 | 56 |
| On enquiry | L | 28 | 41 | 41 | 60 | 27.5 | 58 |
| On enquiry | L | 35 | 50 | 46 | 68 | 25.5 | 61 |
| On enquiry | L | 42 | 60 | 55 | 70 | 24.5 | 65 |
| On enquiry | S | 6 | 17 | 24 | 54 | 24.5 | 50 |
| On enquiry | S | 8 | 19 | 24 | 54 | 24.5 | 50 |
| On enquiry | S | 10 | 22 | 24 | 56 | 23.5 | 50 |
| On enquiry | S | 12 | 24 | 24 | 56 | 23.5 | 50 |
| On enquiry | S | 14 | 27 | 27 | 62 | 26.5 | 51 |
| On enquiry | S | 16 | 30 | 30 | 62 | 25.5 | 53 |
| On enquiry | S | 20 | 36 | 36 | 68 | 25.5 | 56 |
| On enquiry | S | 25 | 46 | 41 | 74 | 26.5 | 58 |
| On enquiry | S | 30 | 50 | 46 | 80 | 27.5 | 61 |
| On enquiry | S | 38 | 60 | 55 | 91 | 29 | 65 |
Reference dimensions support selection. Confirm the supplied item drawing, material, seals and permissible operating conditions with your quotation.

Dimensions in millimetres. Thread designations are shown separately. Match the letters to the drawing.
Catalogue drawing and table — page 58| Fluidline part number | Series | D3 | h | i | Si | T |
|---|---|---|---|---|---|---|
| On enquiry | - | 14 | 38 | 8 | 17 | PF/ 1/8 |
| On enquiry | - | 18 | 36 | 10 | 19 | PF/ 1/4 |
| On enquiry | - | 22 | 36 | 10 | 22 | PF/ 3/8 |
| On enquiry | - | 26 | 26.7 | 14 | 27 | PF/ 1/2 |
| On enquiry | - | 14 | 38 | 8 | 17 | M 10 × 1 |
| On enquiry | - | 17 | 36 | 10 | 19 | M 12 × 1.5 |
| On enquiry | - | 19 | 36 | 10 | 19 | M 14 × 1.5 |
| On enquiry | - | 21 | 36 | 10 | 22 | M 16 × 1.5 |
Reference dimensions support selection. Confirm the supplied item drawing, material, seals and permissible operating conditions with your quotation.

Dimensions in millimetres. Thread designations are shown separately. Match the letters to the drawing.
Catalogue drawing and table — page 66| Fluidline part number | Series | Tube OD (mm) | d | H | h | L | l1 | l2 | T |
|---|---|---|---|---|---|---|---|---|---|
| On enquiry | L | 6 | 2.5 | 14 | 19 | 35.5 | 14.5 | 4.5 | 1/4 |
| On enquiry | S | 6 | 2.5 | 17 | 27 | 42.5 | 20 | 5 | 1/2 |
| On enquiry | S | 6 | 2.5 | 17 | 19 | 35.5 | 14.5 | 4.5 | 1/4 |
Reference dimensions support selection. Confirm the supplied item drawing, material, seals and permissible operating conditions with your quotation.

Dimensions in millimetres. Thread designations are shown separately. Match the letters to the drawing.
Catalogue drawing and table — page 67| Fluidline part number | Series | Tube OD (mm) | d | H | h | L | l1 | l2 | T |
|---|---|---|---|---|---|---|---|---|---|
| On enquiry | L | 6 | 2.5 | 14 | 19 | 38 | 14.5 | 4.5 | 1/4 |
| On enquiry | S | 6 | 2.5 | 17 | 27 | 45 | 20 | 5 | 1/2 |
Reference dimensions support selection. Confirm the supplied item drawing, material, seals and permissible operating conditions with your quotation.
Gauge and test connections support pressure measurement, commissioning and diagnosis. Select them alongside the instrument, isolation arrangement and intended test equipment rather than from fitting appearance alone.
Specify the tube outside diameter, LL/L/S series, material and every connection. The overall catalogue covers 4–42 mm tube, but an individual configuration may have a narrower range. Carbon steel, 316L and 316Ti can be included in an enquiry, subject to confirmation of the supplied item.
State whether you require complete fittings or bodies only. Include working pressure, peak pressure, temperature, medium and any certificate requirements so the complete assembly can be checked.
Select materials, seals and pressure capability →Identify a DIN 2353 connection by tube outside diameter, fitting series, thread and sealing form. A matching thread alone does not establish a correct connection.
Select the fitting, tube and seals as one assembly. Pressure capability depends on the exact configuration, material, tube dimensions, temperature and installation method.
Successful cutting-ring connections depend on suitable tubing, matched components, careful preparation and the correct assembly procedure for the supplied fitting system.
Identify the configuration, tube diameter and series, all connection threads and seals, material, quantity and operating conditions. Send a marked sketch when port positions or different end sizes matter.
Use them to identify and enquire about the configuration. Obtain the order-specific drawing and confirmed pressure rating before fabrication or installation.
Send the connection details and operating conditions. Fluidline can confirm the supplied configuration, availability and supporting documentation with your quotation.
+27 11 312 9339
ram@fluidline.co.za · brett@fluidline.co.za
Send your enquiry directly. We save your requirements and email Brett and Ram so they can respond. Privacy information.