Skip to content
F-Line Hydraulic FittingsDIN 2353 · ISO 8434-1
F-Line TECHNICAL GUIDE

DIN 2353 Pressure Ratings, Materials and Seals

Select the fitting, tube and seals as one assembly. Pressure capability depends on the exact configuration, material, tube dimensions, temperature and installation method.

ISO 8434-1 is the equivalent international standard for DIN 2353 24° cone tube connections.

Published by Fluidline Products · 5 October 2026

Page updated · Fluidline Products (Pty) Ltd

Stainless steel tubing for a correctly specified tube assembly

LL, L & S Pressure and Size Guide

Catalogue pressure ranges by tube outside diameter and fitting material.

Tube OD in mm; catalogue nominal pressure in bar
SeriesTube OD (mm)Steel (bar)Stainless (bar)
LL4, 6, 8, 10, 12100100
L6, 8, 10, 12, 15315250
L18315160
L22160160*
L28, 35, 42160100
S6, 8, 10, 12, 14630630
S16, 20, 25, 30400400
S38315315

Tube sizes are outside diameters (OD) in mm. Pressures are catalogue nominal ratings in bar, not a blanket system working-pressure approval.

* 22 mm stainless L series: 160 bar, confirmed by Fluidline on 20 October 2026. This resolves the overlapping 22 mm ranges in the supplier catalogue.

Check the rating for the exact fitting type: individual configurations can have lower ratings. The lowest permissible limit of the fitting, tube, port and seal governs the assembly. Include tube wall thickness, pressure peaks and temperature when requesting selection.

Stainless column: supplier designation 1.4571 (labelled SS316 in the catalogue). Confirm the supplied material grade; do not automatically transfer these ratings to every stainless alloy.

Brass: the catalogue specifies pressure ratings 30% below the steel values. The steel column is not a brass rating.

No marine class approval is implied by this table. Obtain current certificates and the applicable limits for the specific supplied assembly.

Temperature reductions

Stainless-steel pressure reductions at the listed temperatures: +50°C: 4%; +100°C: 11%; +200°C: 20%; +300°C: 29%; +400°C: 33%. The catalogue shows no reduction from -60°C to +20°C. Confirm intermediate-temperature values with Fluidline; do not infer interpolation. Seal and medium limits can be lower.

Source: Shinilace DIN Bite Type catalogue, printed pages 06-07 (PDF pages 7-8), plus Fluidline clarification of 22 mm stainless L on 20 October 2026.

Download pressure & size guide (PDF)

See the Size & Thread Guide for thread mappings

Define the Operating Duty First

Begin with the fluid, normal working pressure, maximum pressure including peaks, and minimum and maximum operating temperatures. Include start-up conditions and cleaning fluids where relevant. A fitting in a mobile machine may experience a different combination of vibration, pressure cycling and environmental exposure from a fitting on a stationary hydraulic power unit.

Record the tube outside diameter, wall thickness, material and condition. The fitting body is only one part of the pressure boundary. The tube, equipment port, seals and other connected components must all be suitable for the duty. Select using the permissible rating of the complete combination rather than the highest value shown for one component.

Before selecting the material and pressure rating, confirm the tube size and fitting series with the Fluidline DIN 2353 size and thread guide. A matching thread alone does not identify the complete connection.

    Compare Carbon Steel and Stainless Steel

    Carbon steel, 316L stainless steel and 316Ti stainless steel may be specified in an F-Line enquiry, subject to confirmation of the supplied configuration and material. Carbon steel can suit many hydraulic oil installations when its surface protection and the surrounding environment are appropriate. Include exposure to moisture, washdown or coastal conditions when requesting a recommendation.

    Stainless steel can be considered where corrosion resistance is an important selection factor. Identify the required grade explicitly: 316L and 316Ti are different material specifications and should not be treated as identical order descriptions. Suitability still depends on the fluid, concentration, temperature and exposure conditions. Stainless steel does not automatically give a fitting a higher pressure rating than its carbon-steel equivalent.

      Treat Pressure Ratings as Item-Specific Data

      LL, L and S identify fitting series, not one universal working pressure. Within a series, published ratings can change with tube size, material, connection design and fitting configuration. A straight union, banjo connection and adjustable fitting should each be checked against the data for that exact item.

      Temperature can reduce the permissible pressure of a material or assembly. Pressure peaks, repeated cycling, external loads and vibration also need consideration. Request the applicable pressure and temperature data for the proposed part and tube combination. A nominal pressure designation, test pressure or burst pressure must not be used interchangeably as the system working pressure.

        Specify Seals and Tubing Together

        NBR, FKM/FPM and other seal materials have different compatibility and temperature characteristics. Choose a seal for the actual medium and conditions, including any additives or cleaning agents. An O-ring and an ED profile ring are different sealing components; dimensions, profile, material and hardness may all matter. A similar-looking spare seal is not enough to establish suitability.

        Tube selection requires more than matching the outside diameter. Confirm the wall thickness, dimensional tolerances, hardness and preparation requirements for the fitting system. Thin-wall or softer tubing may need an approved support arrangement. Obtain confirmation before making substitutions, and account for the most restrictive temperature and pressure limits across the assembly.

        • Provide the fluid name, composition where relevant, and operating temperature range.
        • State working pressure, maximum peaks, cycling and vibration conditions.
        • Include tube dimensions, material grade, installation environment and required documentation.

        Questions Answered

        What is the pressure rating of an F-Line DIN 2353 fitting?

        It must be confirmed for the selected item, material, tube and temperature. The DIN 2353 designation alone does not establish a single pressure rating for every configuration.

        Can I replace a carbon-steel fitting with stainless steel?

        Request confirmation of dimensions, series, seal compatibility, tube suitability and permissible pressure. A material substitution can change assembly requirements and performance even when the connection dimensions match.

        SPECIFY YOUR CONNECTION

        Request the Right Fitting

        Send the connection details and operating conditions. Fluidline can confirm the supplied configuration, availability and supporting documentation with your quotation.

        +27 11 312 9339
        ram@fluidline.co.za · brett@fluidline.co.za

        Fluidline Products (Pty) Ltd
        Unit 4 Acacia Park, Capital Hill Commercial Estate, Le Roux Avenue, Midrand, 1685, South Africa
        Fluidline contact details →
        DIN Fittings and Technical Enquiries

        Send your enquiry directly. We save your requirements and email Brett and Ram so they can respond. Privacy information.